Title: How can I calibrate the UV content in my Spectrophotometer to measure Whiteness? in Datacolor Tools |
In order to accurately measure materials with optical brighteners or fluorescent colorants, the amount of UV energy emitted by the light source of the spectrophotometer must be controlled.
Read More |
Author: Datacolor |
Created On: 25 Mar, 2009 |
Accessed: 14998 times |
|
Title: Error 3070 when reading Black Trap in Legacy Software |
This error is a Unispef error meaning black trap dianostic failed.
To determine whether is hardware or software problem try running: Terminal program located in ColorTools folder. ... Read More |
Author: Datacolor |
Created On: 24 Mar, 2009 |
Accessed: 10693 times |
|
Title: What is the meaning of the illuminants F2 respectively F11? in Color Theory |
These are standardized illuminants for florescent light. F2 is also named CWF (Cool White Florescent) and F11 is also known as TL84. ... Read More |
Author: Datacolor |
Created On: 8 Mar, 2010 |
Accessed: 9862 times |
|
Title: Invalid White Tile Measurement. Wrong tile? (DF-100) in Retail |
Make sure spectro is connected to com 1 and turned on. If you just received your instrument back from repair, make sure you have switched the loaner instrument out for the returned instrument ... Read More |
Author: Datacolor |
Created On: 24 Mar, 2009 |
Accessed: 9810 times |
|
Title: Error 23021: Communication to instrument failed! Please check power and connection. in Spectrophotometers |
Cause:
User inadvertently used Fluorescent tile during calibration instead of White ceramic tile.
Solution:
Calibrate the instrument with the correct White tile. ... Read More |
Author: Datacolor |
Created On: 20 Dec, 2010 |
Accessed: 9467 times |
|
Title: UV Calibration and Whiteness FAQs in Datacolor Tools |
Read More |
Author: Datacolor |
Created On: 25 Mar, 2010 |
Accessed: 9433 times |
|
Title: Where can you find the information needed for license validation? in Software |
The serial number of the software license is located on the CD case, on a white sticker. It contains the product name, order numbe ... Read More |
Author: Datacolor |
Created On: 17 Nov, 2010 |
Accessed: 9349 times |
|
Title: This control NoSpec.Dll does not support a measurement device. in Retail |
The spectrophotometer control has not been properly installed on this machine when booting Paintmaker.
Make sure the instrument is connected to com1 and turned on. If you just got your ... Read More |
Author: Datacolor |
Created On: 1 Apr, 2009 |
Accessed: 8559 times |
|
Title: How do I install new white tile calibration data in Datacolor Paint? in Retail |
If you have received a new white tile and data after an instrument was repaired, please see attached instructions for replacing the white tile ... Read More |
Author: Datacolor |
Created On: 22 Sep, 2010 |
Accessed: 8445 times |
|
Title: How do I store a new diagnostic tile measurement in Paintmaker or Datacolor Paint, if I have replaced my white tile, or changed instruments? in Retail |
Delete the file: diagtile.ini
located in:
For Datacolor Paint, delete it from this folder:
C:\Program Files\datacolor\Spectrum\Datacolor Paint
For Paintmaker ... Read More |
Author: Datacolor |
Created On: 17 Jun, 2009 |
Accessed: 8107 times |
|
Title: During the Back trap calibration, the instrument does not flash and the software quickly asks for the White tile. in Spectrophotometers |
Cause:
The instrument does not communicate with the PC, the instrument goes automatically on Simulus mode.
Solutions:
Check the cable,
Restart the instrument,
... Read More |
Author: Datacolor |
Created On: 18 Feb, 2010 |
Accessed: 8055 times |
|
Title: UV calibration sometimes gives negative whiteness values. in Datacolor Tools |
Problem in the instrument driver. Contact your local Datacolor support office for the latest version of instrument drivers. ... Read More |
Author: Datacolor |
Created On: 25 Mar, 2009 |
Accessed: 7898 times |
|
Title: How do I change the standard measurement of my instrument’s diagnostic tile? in Datacolor Tools |
If you have changed the calibrating white tile for your instrument, you will need to delete the standard measurement of your diagnostics tile. To do so, select Instrument menu, Instrument Setup, Gen ... Read More |
Author: Datacolor |
Created On: 13 Apr, 2009 |
Accessed: 7846 times |
|
Title: Just downloaded instrument data from e-mail, how do I load the new calibration data? in Retail |
Make sure spectro is connected to com 1 and turned on. If you just received your instrument back from repair, make sure you have switched the loaner instrument out for the returned instrument b ... Read More |
Author: Datacolor |
Created On: 24 Mar, 2009 |
Accessed: 7845 times |
|
Title: How do I set up a loaner instrument? in Retail |
Make sure your instrument is connected to com1 and turned on. If you just got your instrument back from repair, make sure you have switched the loaner instrument out for the returned instrument b ... Read More |
Author: Datacolor |
Created On: 1 Apr, 2009 |
Accessed: 7722 times |
|