What does error after monitor calibration "Error:unknown error:(536936466) [20010012] generate icc profile:CopyProfileWithICM 360
That error after calibration is coming from a permissions
issue on a folder where Envision is trying to copy a calibration file.
The file it is trying to copy is actually an ICC profile that is not used by
Envision. The calibration program creates this ICC profile so that it can
be used in other programs. This means that the calibration files in
Envision were created properly and that the error will not affect what you are
doing in Envision.
We can get rid of the message by figuring out what folder
the user does not have write-permission on, but finding the folder can be trick
y. It’s operating system dependent, and on Windows XP or 7
it is usually “C:WINDOWS\system3spool\drivers\color”. If it’s not
there try searching for *.icc to see what folder they are located in.
Once you find this folder, an administrator can give “write” permission on that
folder. Then there will no longer be any error message.
Click Here to View all the questions in Datacolor Tools
category.