Home > All Categories > Software > Industrial > Datacolor Tools > How do I change the number of measurements to default to, for an average?
Question Title How do I change the number of measurements to default to, for an average?
On the Datacolor Tools Instrument menu, select Instrument Setup, and General Options tab.  Then, select the folder, Multiple Measurement.  In the box labeled Number of Readings, change it to the preferred number of measurements to average.  Click Save Options button.
 

Click Here to View all the questions in Datacolor Tools category.
Related Questions Related Questions
  1. How to import/export QTX files in Datacolor Tools?
  2. Datacolor Tools does not start or crash after login
  3. I am getting Overflow error or math errors in Datacolor Tools
  4. How can I calibrate the UV content in my Spectrophotometer to measure Whiteness?
  5. Datacolor QTX File Specification
  6. It’s not possible to start Datacolor Tools after a new installation and I don’t get an error message.
  7. How do I insert a sample manually?(L*,a*,b* coordinates or Reflectance values)
  8. Datacolor Tools v.2 Quick Start Guide
  9. How to use Datacolor Tools to determine Haze?
  10. What are best practices for measuring textile samples?
  11. Where can I find Walmart Forms and Templates?
  12. UV Calibration and Whiteness FAQs
  13. How do I solve the error, "GeneralDataSecurityException: LoggedOn, Cannot connect to the remote host"
  14. What type of calculation does Datacolor Tools use for metamerism index?
  15. Walmart Process for Datacolor Tools 2.0
  16. Is our Datacolor Tools 1.x software going to work with Windows7 ?
  17. Green tile test gives unstable results when TOOLS is connected to Microflash 45 IR (MF45 IR)
  18. After starting Dtools,"GeneralDataSecurity Exception:Initialize Database failure Specified Database not found, Err1:-83 Err2:1, Vendor 1 08003, [Sybase][ODBC Driver] [Adaptive Server Anywhere] D
  19. How to change color tolerances?
  20. System runs slowly / Sometimes after measuring samples, the data is very slow to be displayed in Datacolor Tools.
  21. Imported samples from QTX files cannot be stored into the database, possible error messages "Sybase ODBC error - - Column Sample ID in standard table cannot be null." or "[Sybase][ODBC
  22. Error message when opening Tools 1.2 : "This form has been created to use illuminant #85712 but there are only three active illuminants. Will adjust to current illuminant!".
  23. Strength methods in Datacolor Tools 2.x
  24. Datacolor Tools 1.3 release version does not let me calibrate my MF45 and MF45IR.
  25. Emailing measurement data from Tools QC
  26. How to enable the top menu?
  27. How to use Customized Filters in Datacolor Tools?
  28. How to Change illuminant/Observer ?
  29. How to change the Standard- or Batchname, if the description is not correct.
  30. How to print forms in Tools?
  31. How do I remove the gray background on the printout of reflectance plots in Datacolor Tools?
  32. UV calibration sometimes gives negative whiteness values.
  33. How to change Tolerance Limit?
  34. Imported samples from QTX files cannot be stored into the database,possible error messages "Sybase ODBC error - - Column Sample ID in standard table cannot be null." or "[Sybase][ODBC D
  35. How do I create general tolerances in Datacolor Tools 1.x?
  36. How do I download the latest Wal-Mart forms?
  37. Solving Common Problems with Datacolor Tools
  38. How do I change the standard measurement of my instrument’s diagnostic tile?
  39. Where can I locate Tools_Global and the .FRM files in Windows Vista?
  40. After measuring or retrieving a sample, I get errors "math domain, power overflow."
  41. How do I create/add user fields in Tools?
  42. How do I save the current screen form so that it appears every time I start Datacolor Tools?
  43. How can I export samples from my TOOLS desktop to another TOOLS user?
  44. AATCC UV Calibration Procedure
  45. How can I retrieve my samples I stored in the Match program, into Datacolor Tools?
  46. Cleaning up DatacolorTools-Copying data from one folder to another and deleting folders
  47. How to Change Measurement mode from Single to Average and make it a default setting?
  48. When we try to open Tools we are getting this error:
  49. How to Add Labels in Graphs?
  50. How do I change the time between instrument calibrations?
  51. Cannot edit button bars
  52. How do I setup the green tile reading for optional?
  53. How do I export information from my template in Datacolor Tools 2.x to Excel
  54. What is contrast ratio and how do I use it?
  55. What does error after monitor calibration "Error:unknown error:(536936466) [20010012] generate icc profile:CopyProfileWithICM 360
  56. Can I use Datacolor Tools to evaluate high visibility and safety apparel with ANSI 107?
  57. How do I display the Gray Scale for Staining and Gray Scale for Color Change in Datacolor Tools?
  58. How do I add the CSI Color Solutions International colorwall into Tools for Search
  59. How can I search my Tools database for a color close to a new color standard?
  60. What is APHA10 and how is it used in Tools QC?
  61. How do I create an Artificial Intelligence tolerance in Tools 2.x?
Article Information Additional Information
Article Number: 162
Created: 2009-04-13 10:33 PM
 
Article Options Article Options
Print Question Print this Question
Export to Adobe PDF Export to PDF File
 
Language Translation Language Translation
 
Search Knowledge Base Search Knowledge Base
 
     

Powered by PHPKB Knowledge Base Software